Navien NCB-250/150H 150,000 BTU Heating / 199,000 BTU DHW High Capacity Condensing Combi Boiler
✓ 150K BTU/h H | 199K BTU/h DHW
✓ up to 95% AFUE
✓ 15-year heat exchanger warranty
NAVIEN Combi Boiler NFC-250/175H , 175,000 BTU Heating, 250,000 BTU Water Heating
✓ 175K BTU/h H | 210K BTU/h DHW
✓ 10.8 GPM max flow rate
✓ 15-Year Heat Exchanger | 5 Year Parts
Navien NCB-240/130H 130,000 BTU Heating / 199,000 BTU DHW High Output Condensing Combi Boiler
✓ 130K BTU/h H | 199K BTU/h DHW
✓ up to 95% AFUE
✓ 15-year heat exchanger warranty
Navien NCB-190/080H 80,000 BTU Heating / 160,000 BTU DHW Condensing Combi Boiler
✓ 80K BTU/h H | 199K BTU/h DHW
✓ up to 95% AFUE
✓ 15-year heat exchanger warranty
NAVIEN Combi Boiler NFC-250/200H , 199,000 BTU Heating, 210,000 BTU Water Heating
✓ 199K BTU/h H | 210K BTU/h DHW
✓ 95% AFUE High-Efficiency Condensing
✓ 15-Year Heat Exchanger | 5 Year Parts
Navien NCB-190/060H 60,000 BTU Heating / 160,000 BTU DHW Condensing Combi Boiler
✓ 60K BTU/h H | 160K BTU/h DHW
✓ up to 95% AFUE
✓ 15-year heat exchanger warranty
YOU MAY ALSO BE INTERESTED IN:
Heat Only Boiler Options
Rinnai IP150S Heat Only Boiler 150,000 BTU I-Series Plus
Rinnai IP199S Heat Only Boiler 199,000 BTU I-Series Plus
Rinnai Boiler IP120S Heat Only 120,000 BTU I-Series Plus
NAVIEN Boiler NFB-175H 175,000 BTU
$3,706.00NAVIEN Boiler NFB-200H 199,000 BTU
$3,978.00NAVIEN Boiler NHB-110H 110,000 BTU
$3,079.00NAVIEN Boiler NHB-150H 150,000 BTU
$3,443.00Navien Boiler NHB-55H, 55,000 BTU
$2,569.00NAVIEN Boiler NHB-80H, 80,000 BTU
$2,815.00Navien NFC-250/200H – Supplied & Professionally Installed by 4Most Energy
The Navien NFC-250/200H combines space heating and domestic hot water in one high-capacity condensing appliance. It delivers up to 199,900 BTU/h of heating input, up to 210,000 BTU/h of DHW input, and 95% AFUE, making it a high-output option for homes requiring substantial heating and hot-water performance. The unit uses a patented stainless steel fire tube heat exchanger and a separate stainless steel DHW heat exchanger.
Installation requires careful consideration of the existing hydronic system, gas supply, electrical service, venting, combustion air, condensate drainage and domestic-water connections. The NFC-250/200H is an indoor wall-hung appliance with forced-draft direct venting. Navien permits 2" or 3" approved venting materials, with 2" venting up to 65 feet and 3" venting up to 150 feet under the applicable installation requirements. The unit also provides 1/2" gas-pipe capability for runs up to 24 feet, subject to local code and installation conditions.
The system operates from a 120V AC, 60Hz electrical supply and includes an integrated boiler pump, built-in controls for up to three zone pumps or zone valves, and an advanced user interface with Setup Wizard.
Proper sizing is critical. Navien recommends determining combi-boiler capacity using both a building heat-loss calculation and domestic-hot-water demand. 4Most Energy can evaluate the existing system and recommend equipment based on the actual heating and hot-water requirements rather than selecting a boiler solely by home square footage.
Documents
Why Install the NFC-250/200H with 4Most Energy?
- 95% AFUE high-efficiency condensing operation.
- Up to 199,900 BTU/h heating input and 210,000 BTU/h DHW input.
- 15:1 turndown ratio for both heating and domestic hot water.
- Patented stainless steel fire tube heat exchanger with ASME certification and “H” stamping.
- Separate stainless steel DHW heat exchanger with flow capability up to 5.4 GPM at a 70°F temperature rise.
- Built-in control for up to three zone pumps or three zone valves.
- Integrated boiler pump and accessible DHW module.
- Advanced backlit user interface with intuitive text display and Setup Wizard.
- Dual Venturi system for combustion control and field gas conversion capability.
- Vent Installation Detector (VID) for additional venting safety.
- High-altitude approval up to 10,100 feet for NG and LP applications.
| Specification | Value |
|---|---|
| Model | NFC-250/200H |
| Product Type | Condensing Combi-Boiler |
| Heating Input | 13,300–199,900 BTU/h |
| Heating Capacity | 183,000 BTU/h |
| Net AHRI Water Rating | 159,000 BTU/h |
| DHW Input | 13,000–210,000 BTU/h |
| AFUE | 95.0% |
| DHW Flow @ 45°F Rise | 8.4 GPM |
| DHW Flow @ 70°F Rise | 5.4 GPM |
| Fuel | Natural Gas / Propane conversion capability |
| Installation | Indoor, wall-hung |
| Venting Type | Forced-draft direct vent |
| Venting | 2" or 3" PVC, CPVC, approved polypropylene, special gas vent or stainless steel |
| Maximum 2" Venting | Up to 65 ft |
| Maximum 3" Venting | Up to 150 ft |
| Electrical | 120V AC, 60Hz |
| Maximum Power Consumption | Less than 15 amperes |
| Heating Supply/Return | 1" NPT |
| DHW Connections | 3/4" NPT |
| Gas Connection | 3/4" NPT |
| Dimensions | 17.3" W × 17.3" D × 33.5" H |
| Boiler Weight | 141 lb |
| Weight With Water | 170 lb |
| Heat Exchanger Material | Stainless steel |
| Water Pressure — Heating | 12–80 PSI |
| Water Pressure — DHW | 15–150 PSI |
| Ignition | Electronic |
| Model | Maximum Heating Input | Maximum DHW Input | Application Guidance |
|---|---|---|---|
| NFC-250/200H | 199,900 BTU/h | 210,000 BTU/h | For applications requiring up to 199,900 BTU/h heating input |
Important Sizing Note
Manufacturer house-size recommendations are not provided. Navien states that combi-boiler sizing should be based on:
- Building heat-loss calculation
- Structure size and insulation
- Doors and windows
- Domestic hot-water fixture demand
- Required maximum DHW flow
Therefore, a specific square-footage or occupant recommendation should not be assigned without a proper load calculation.
DHW Performance Reference
At a 70°F temperature rise, the NFC-250/200H is rated for up to 5.4 GPM. The supplied brochure describes the NFC-H DHW system as capable of supporting up to three showers and a dishwasher simultaneously under the stated conditions.
1. Request Installation Quote Contact 4Most Energy to discuss the existing heating and hot-water system.
2. System Sizing Consultation The heating load and domestic-hot-water requirements are evaluated to determine appropriate equipment sizing.
3. Equipment Recommendation 4Most Energy reviews the application and recommends the appropriate Navien combi-boiler and required installation components.
4. Installation Scheduling Once the project scope is approved, an installation date is arranged.
5. Removal of Existing Equipment Existing boiler and/or water-heating equipment is removed where included in the project scope.
6. Installation & System Connection The NFC-250/200H is wall-mounted and connected to the heating system, domestic water, gas, electrical supply, venting and condensate drainage as required.
7. Safety Testing Gas, water, electrical, venting and combustion-related installation components are checked in accordance with applicable requirements.
8. Final Commissioning The boiler controls are configured and the system is operated to verify proper heating and domestic-hot-water performance.
For single-family residential applications, Navien lists:
| Warranty Coverage | Residential* | Commercial |
|---|---|---|
| Heat Exchanger | 10 Years | 5 Years |
| Parts | 5 Years | 3 Years |
| Labor | 1 Year | 1 Year |
For commercial applications, Navien lists 5 years heat exchanger, 3 years parts and 1 year labor.
Warranty Claim Process
For a suspected warranty issue, the homeowner should contact the original installer or an authorized Navien service resource. Navien states that technical support may require the unit's serial number and registration information, including installation date, homeowner information and installer information before replacement parts can be issued.
Warranty coverage is subject to Navien's complete warranty terms and applicable conditions.
4Most Energy labour warranty:
Insert the current 4Most Energy labour-warranty terms applicable to this installation. The Navien manufacturer's 1-year labor coverage should not be represented as a separate 4Most Energy labor warranty.
Optional Maintenance Plan
Maintenance plans starting from $12.99/month
A maintenance plan can help keep the combi-boiler operating properly through scheduled professional service and system checks. Enrollment is optional and can be discussed with 4Most Energy.
Benefits may include:
- Scheduled system maintenance
- Performance checks
- Early identification of service issues
- Professional system inspection
- Maintenance records
Enrollment and exact inclusions should follow the current 4Most Energy maintenance-plan terms.
Service Area
Greater Toronto Area (GTA) and surrounding regions
Toronto, Markham, Richmond Hill, Vaughan, Aurora, Newmarket, Scarborough, Brampton, and Mississauga.
Extended Service Area: Stouffville, Oshawa, Barrie, Orangeville, Hamilton, St. Catharines, Guelph, Kitchener.