Hayward Heat Pump Pool Heater
Hayward HP80CLEE1 Variable-Speed Pool Heat Pump (79,000 BTU)
Heat Pump pool heater Hayward HeatPro VS Titanium Inverter 115,000 BTU Variable Speed
Moov Heat Pump Pool Heater

Moov Inverter Pool Heat Pump – Supplied & Professionally Installed by 4Most Energy
When it comes to a premium pool heater replacement, securing a highly efficient system is only half the equation; the execution of the install dictates its lifespan and operational safety. The Moov Inverter offers outputs ranging from 50,000 BTU to 140,000 BTU, making it highly adaptable, but it requires precise electrical integration and spatial planning to achieve its staggering thermal efficiencies. As your trusted Moov Inverter certified installer, 4Most Energy ensures that every high-voltage electrical connection, dedicated 208-230V circuit, and structural bonding strictly adheres to Electrical Safety Authority (ESA) and local building standards.
Unlike uncertified contractors or standard big-box retail purchases that leave you liable for safety hazards and voided warranties, our licensed technicians guarantee a code-compliant installation built for long-term reliability and complete peace of mind. We calculate precise water flow dynamics—accommodating up to 167 L/min—and secure mandatory operational clearances (minimum 20 inches circumferentially and 8 feet vertical clearance for air discharge) to prevent equipment-killing air recirculation. Whether you are building a new backyard oasis or replacing an outdated, energy-draining unit, trust 4Most Energy for your Moov Inverter pool heat pump installation Southern Ontario. We seamlessly tie this into your broader home comfort ecosystem, bringing the same rigorous standards we apply to our high-efficiency HVAC upgrades and new boiler installation services, ensuring your entire property operates flawlessly.
Manufacturer Warranty: 3-Year Parts & Labor | 5-Year Compressor & Titanium Heat Exchanger (Parts).
Features:
- Full Inverter Technology: Intelligently adjusts compressor and fan speed between 20% and 100% to match real-time heating demands, resulting in an average COP of 8.0 (producing 8kW of heat for every 1kW of electricity consumed).
- Unparalleled Acoustic Control: Operates at an incredibly low 48 dB(A) at 1 meter in Silence Mode—up to 7 times quieter than traditional on/off heat pumps, equivalent to the sound of a quiet refrigerator.
- Twin-Rotary DC Compressor: Two rotors operate synchronously to balance torque, providing anti-shaking stability, higher efficiency, and quieter operation.
- Spiral Titanium Heat Exchanger: Features a 30% enlarged heat-exchanging surface and HP-BOOSTER technology to ensure maximum thermal transfer and absolute resistance to salt and chemical corrosion.
- Soft Start Technology: Current ramps up gradually from 0A to the rated current over two minutes, preventing electrical surges and protecting your home's breaker panel.
MI Series Pool Heat Pump Specifications
| Model | Max Pool Volume (Gallons) |
Heating Capacity (BTU) |
COP Range | Power Supply | Rated Current (A) |
Breaker |
|---|---|---|---|---|---|---|
| MI500 | Up to 14,000 | 50,000 | 10.6 – 5.98 | 208-230V | 2.00 – 11.0 | 20A / 30A |
| MI650 | Up to 18,000 | 66,000 | 11.2 – 5.61 | 208-230V | 2.30 – 14.8 | 30A |
| MI900 | Up to 28,000 | 90,000 | 13.6 – 6.0 | 208-230V | 2.34 – 19.1 | 30A |
| MI1100 | Up to 32,000 | 110,000 | 13.5 – 5.8 | 208-230V | 2.65 – 25.6 | 40A |
| MI1400 | Up to 42,000 | 140,000 | 13.1 – 5.8 | 208-230V | 3.69 – 29.8 | 50A |
⚡ Performance condition: Air 80°F / Water 80°F / Humidity 80%.
Sizing Guide
Proper sizing is critical for the cold shoulder seasons in Southern Ontario.
While the MI500 is engineered for smaller pools up to 14,000 gallons, larger builds will require the MI1100 or MI1400 (handling up to 42,000 gallons).
We calculate your specific thermal load based on surface area, wind exposure, and desired temperature rise. Integrating this unit with modern variable speed pool pumps ensures the optimal required water flow (83 to 167 L/min) is maintained efficiently, maximizing the heat pump's COP without wasting electrical energy.
Professional Installation Process
- Site Assessment & Pad Preparation: We evaluate the equipment pad to ensure a solid, level concrete or composite foundation, maintaining mandatory manufacturer clearances (minimum 20 inches around the unit, and unrestricted overhead clearance for vertical discharge models).
- Electrical Integration: A dedicated 208-230V circuit is hardwired to the unit's terminal board. We verify breaker sizing (ranging from 30A to 50A depending on the model) and strictly adhere to ESA grounding and bonding protocols.
- Hydraulic Plumbing: The unit is plumbed into your filtration loop after the filter and before any chemical chlorinators. We utilize high-temperature PVC and install bypass valves for precise flow regulation and easy winterization.
- Commissioning & Testing: We boot the system, testing the Inverter's Soft Start protocol, verifying pressure limits (High ≤609 PSIG, Low ≤261 PSIG), and configuring the Smart/Silence modes on the digital interface for optimal customer use.
Warranty and Longevity
The Moov Inverter is backed by a robust manufacturer warranty when installed by certified professionals:
- 3 Years: Comprehensive coverage on Parts & Labor.
- 5 Years: Extended parts coverage on the Titanium Heat Exchanger and Compressor.
Important: To maintain the integrity of the titanium heat exchanger and keep your warranty valid, strict adherence to optimal water chemistry is required: pH 7.4-7.6, Alkalinity 80-120 ppm, and appropriate sanitation levels. Warranty exclusions apply to damage caused by improper winterization (freezing), insufficient water flow, or severe chemical imbalances.
Swimming Pool Service Area
Greater Toronto Area (GTA) and surrounding regions
Toronto, Markham, Richmond Hill, Vaughan, Aurora, Newmarket, Scarborough, Brampton, and Mississauga.
Extended Service Area: Stouffville, Oshawa, Barrie, Orangeville, Hamilton, St. Catharines, Guelph, Kitchener.
Frequently Asked Questions
Is the Moov Inverter pool heat pump suitable for the Southern Ontario climate?
Yes. The Moov Inverter is specifically engineered to operate efficiently in variable climates. It can function in ambient air temperatures as low as 32°F (0°C), making it exceptional for extending your swimming season through the chilly Southern Ontario spring and fall.
How much energy can I save by switching to an inverter pool heat pump?
Compared to traditional on/off pool heat pumps that run constantly at maximum capacity, the Moov Inverter uses intelligent modulation to maintain temperatures at lower speeds. This results in up to 50% higher energy savings and an average Coefficient of Performance (COP) of 8.0.
What electrical requirements are needed for the Moov Inverter series?
These units require a dedicated 208-230V/1Ph/60Hz electrical supply. Depending on the exact model (MI500 up to MI1400), a dedicated breaker ranging from 30A to 50A is required. Our certified installers ensure all wiring meets strict ESA codes.
How quiet is the Moov Inverter compared to traditional pool heaters?
The Moov Inverter is remarkably quiet. Operating at just 48 dB(A) at 1 meter in Silence Mode, it is up to 7 times quieter than conventional heat pumps—roughly equivalent to the hum of a standard household refrigerator.
Do I need a specific water flow rate for this pool heater to work correctly?
Yes. To achieve maximum thermal transfer and prevent system errors, proper water flow is mandatory. Required flow rates range from 83 L/min for the MI500 up to 167 L/min for the larger MI1400 model. We measure and adjust this during the professional installation process.
Can the Moov Inverter both heat and cool my swimming pool?
Specific models within the Moov Inverter lineup (those with the "MIC" codification) feature an Auto Mode that provides both heating (adjustable up to 104°F) and active cooling (adjustable down to 54°F) capabilities to maintain perfect water temperatures during intense summer heatwaves.
