Bladex BLGV96M Gas Furnace – Supplied & Professionally Installed by 4Most Energy
The Bladex BLGV96M gas furnace series is designed for high-efficiency residential heating with 96 AFUE performance across all listed models. Its two-stage gas valve allows the furnace to operate at lower or higher firing rates depending on heating demand, helping improve comfort compared with single-stage operation. The furnace also uses a durable aluminized steel tubular heat exchanger, hot surface igniter, and quiet multi-speed ECM motor for dependable heating and airflow performance.
The BLGV96M series is convertible for natural gas or propane applications, making it suitable for different residential fuel setups when properly configured by a qualified technician. Available heating inputs range from 60,000 to 120,000 BTU/h, with listed high-fire outputs from 57,000 to 115,000 BTU/h depending on model and fuel type.
Installation requires proper furnace sizing, gas line verification, electrical connection, venting design, condensate management, and ductwork compatibility review. The manufacturer lists 2-inch or 3-inch vent diameter requirements depending on model, with the 120,000 BTU/h model using a 3-inch vent diameter. Because this is a high-efficiency furnace, venting and drainage must be installed according to manufacturer requirements and local code.
4Most Energy supplies and installs the BLGV96M series with a focus on correct model selection, safe gas connection, proper airflow setup, and final commissioning. A heating load review is recommended before installation to ensure the selected furnace capacity matches the home rather than simply replacing the old unit with the same size.
Why Install the Bladex XHeat Series with 4Most Energy?
96 AFUE high-efficiency gas heating performance across all listed BLGV96M models.
Two-stage gas valve for low-fire and high-fire heating operation.
Durable aluminized steel tubular heat exchanger.
Hot surface igniter for reliable ignition.
Quiet multi-speed ECM motor.
Natural gas and propane convertible design.
Metal circulator blower construction.
Five-speed blower mode across the listed model range.
| Specification | BLGV96M060B3B | BLGV96M080B3B | BLGV96M080C4B | BLGV96M100C5A | BLGV96M100D5A | BLGV96M120D5A |
| Fuel Type | Natural / Propane Gas | Natural / Propane Gas | Natural / Propane Gas | Natural / Propane Gas | Natural / Propane Gas | Natural / Propane Gas |
| High Fire Input | 60,000 BTU/h | 80,000 BTU/h | 80,000 BTU/h | 100,000 BTU/h | 100,000 BTU/h | 120,000 BTU/h |
| High Fire Output – Natural Gas | 57,000 BTU/h | 76,000 BTU/h | 76,000 BTU/h | 95,000 BTU/h | 95,000 BTU/h | 115,000 BTU/h |
| High Fire Output – LP Gas | 57,000 BTU/h | 76,000 BTU/h | 76,000 BTU/h | 95,000 BTU/h | 95,000 BTU/h | 115,000 BTU/h |
| Low Fire Input | 39,000 BTU/h | 52,000 BTU/h | 52,000 BTU/h | 65,000 BTU/h | 65,000 BTU/h | 78,000 BTU/h |
| Low Fire Output – Natural Gas | 37,000 BTU/h | 49,000 BTU/h | 49,000 BTU/h | 62,000 BTU/h | 62,000 BTU/h | 75,000 BTU/h |
| Low Fire Output – LP Gas | 37,000 BTU/h | 49,000 BTU/h | 49,000 BTU/h | 62,000 BTU/h | 62,000 BTU/h | 75,000 BTU/h |
| Efficiency | 96 AFUE | 96 AFUE | 96 AFUE | 96 AFUE | 96 AFUE | 96 AFUE |
| Available AC @ 0.5 in. ESP | 1.5 / 2 / 2.5 / 3 ton | 1.5 / 2 / 2.5 / 3 ton | 2.5 / 3 / 3.5 / 4 ton | 3.5 / 4 / 4.5 / 5 ton | 3.5 / 4 / 4.5 / 5 ton | 3.5 / 4 / 4.5 / 5 ton |
| Model | Capacity | Recommended House Size | Recommended Occupants |
|---|---|---|---|
| BLGV96M060B3B | 60,000 BTU/h input | Smaller homes or lower heat-loss applications; sizing required | Typically 1–3 occupants |
| BLGV96M080B3B | 80,000 BTU/h input | Small to mid-size homes; sizing required | Typically 2–4 occupants |
| BLGV96M080C4B | 80,000 BTU/h input | Small to mid-size homes requiring higher airflow; sizing required | Typically 2–4 occupants |
| BLGV96M100C5A | 100,000 BTU/h input | Larger homes or higher heat-loss applications; sizing required | Typically 3–5 occupants |
| BLGV96M100D5A | 100,000 BTU/h input | Larger homes needing higher airflow support; sizing required | Typically 3–5 occupants |
| BLGV96M120D5A | 120,000 BTU/h input |
Installation Journey
Request installation quote
Submit your furnace replacement or new installation request to 4Most Energy.System sizing consultation
A technician reviews heating requirements, existing equipment, ductwork, venting, and gas supply.Equipment recommendation
4Most Energy recommends the appropriate BLGV96M model based on capacity, airflow, fuel type, and installation conditions.Installation scheduling
Installation is scheduled after the equipment selection and quote are approved.Removal of existing equipment
The existing furnace is safely disconnected and removed where replacement is required.Installation and system connection
The new furnace is installed and connected to approved gas, electrical, venting, condensate, thermostat, and ductwork systems.Safety testing
Gas connections, ignition, venting, condensate drainage, electrical operation, and airflow are checked.Final commissioning
The furnace is tested through operating stages and reviewed with the homeowner before completion.
Payment Process
Payment terms are confirmed before installation. The approved quote outlines equipment cost, installation labour, included materials, exclusions, taxes, and any available financing or maintenance plan options.
Manufacturer Warranty
Bladex lists a 10-year warranty on parts and compressors, along with after-sales support, local spare parts availability, a technical support team, and warranty registration channels. Warranty eligibility may depend on proper installation, registration, maintenance, and manufacturer terms.
4Most Energy Labour Warranty
4Most Energy provides labour warranty coverage according to the approved installation agreement. Labour warranty terms should be confirmed at the time of quote and may vary depending on installation scope and service package.
Warranty Claim Process
Contact 4Most Energy with the model number, installation date, and issue description.
A technician reviews the system and determines whether the issue relates to installation, service, or a manufacturer part.
If a covered manufacturer part is involved, 4Most Energy assists with warranty processing where applicable.
Approved repairs or replacements are completed based on manufacturer warranty terms and labour coverage.
Optional Maintenance Plan
Maintenance plans starting from $12.99/month
A maintenance plan helps keep the furnace operating safely and efficiently. Plan benefits may include scheduled maintenance reminders, system inspection, priority service options, and support with identifying issues before they become larger repairs.
Enrollment can be completed during installation booking or after the furnace is installed. Final plan details, coverage, and pricing should be confirmed with 4Most Energy before enrollment.