Hayward Heat Pump Pool Heater
Hayward HP80CLEE1 Variable-Speed Pool Heat Pump (79,000 BTU)
Heat Pump pool heater Hayward HeatPro VS Titanium Inverter 115,000 BTU Variable Speed
Moov Heat Pump Pool Heater

Hayward HP115CLEE1 HeatPro VS – Supplied & Professionally Installed by 4Most Energy
As Southern Ontario’s premier authority in high-performance aquatic heating, 4Most Energy engineers and executes rigorous, code-compliant pool heater replacement and installations. The Hayward HP115CLEE1 is an advanced variable-speed heat pump demanding precise electrical sizing and hydraulic balancing. Unlike conventional gas systems governed by TSSA standards, integrating this 115,000 BTU/hr electric heat pump requires strict adherence to Ontario Electrical Safety Authority (ESA) regulations, including a dedicated 208-230V circuit and heavy-gauge equipotential bonding to eliminate stray voltage risks.
Our licensed electrical technicians ensure your system is meticulously calibrated for maximum efficiency, maintaining precise water flow rates (16 to 40 GPM) to achieve its certified Coefficient of Performance (COP) of 5.0. For authoritative electric pool heater installation Southern Ontario, property owners trust our Hayward HP115CLEE1 certified installer team to navigate local climate demands and strict equipment pad clearances. Proper integration of the inverter compressor requires exacting hydraulic calculations to prevent high-pressure lockouts and maximize heat transfer during shoulder seasons. Choosing our certified installation guarantees long-term thermal reliability and absolute safety, contrasting sharply with the premature equipment failures and voided warranties common with standard big-box retail purchases or uncertified contractors.
Manufacturer Warranty Highlight:
Features Hayward’s tiered warranty system—1-year standard, 2-year non-ASME pro install, and 3-year ASME pro install on parts. Strict adherence to water chemistry requirements is mandatory.
Performance Features
- Inverter Compressor Technology: Modulates power output precisely to demand, reducing energy consumption by up to 50% compared to single-speed traditional heat pumps.
- Acoustic Dampening: The variable-speed fan and insulated compressor compartment yield a swimming environment up to 10 times quieter than legacy models.
- Cold-Climate Adaptability: Maintains an impressive 56,300 BTU/hr heating capacity even at lower air temperatures (Low Air/Mid Humidity AHRI rating), crucial for extending the Canadian swim season.
- Eco-Friendly Heat Transfer: Utilizes highly efficient R-410A refrigerant coupled with a corrosion-resistant heat exchanger.
| Specification | Technical Detail |
|---|---|
| Model Number | HP115CLEE1 |
| Heating Capacity (High Air/High Humidity) | 115,000 BTU/hr |
| Heating Capacity (Low Air/Mid Humidity) | 56,300 BTU/hr |
| Max Coefficient of Performance (COP) | 5.0 |
| Refrigerant Type | R-410A |
| Electrical Supply | 208-230V / 1 Phase / 60Hz |
| Water Flow Rate (Min/Max) | 16 GPM / 40 GPM |
| Minimum Circuit Amps (MCA) |
The 4Most Energy Installation Process
Just as we apply strict engineering protocols for our indoor new boiler installation and high-efficiency HVAC upgrades, our pool heater deployments follow rigid electrical and hydraulic specifications:
Site & Load Calculation: We verify pad clearances and calculate the exact BTU load required based on pool volume and wind exposure.
Electrical Integration: Complete code-compliant wiring, installing appropriately sized breakers, local disconnects, and verifying continuous equipotential bonding (ESA standards).
Hydraulic Calibration: Hard-piping the unit into the return line with appropriately sized bypass valves to guarantee flow remains strictly between 16 and 40 GPM.
System Commissioning: Firing the inverter compressor, verifying R-410A refrigerant pressures, and programming the user interface for optimal setpoints.
Sizing Guide for Southern Ontario
In the cold Southern Ontario climate, selecting the correct heat pump requires factoring in rapid overnight temperature drops and high wind exposure. A 115,000 BTU unit is generally optimal for medium-to-large residential pools, provided a solar cover is utilized. Because variable-speed heat pumps thrive on consistent, low-flow circulation to extract ambient heat efficiently, integrating variable speed pool pumps into your hydraulic system ensures optimal heat transfer without exceeding the heat exchanger's maximum GPM limits.
Warranty and Longevity Restrictions
Tiered Protection: 1-year standard warranty; 2-year non-ASME pro install warranty; 3-year ASME pro install warranty.
Critical Water Chemistry Requirements: To maintain warranty validity, water chemistry must be strictly maintained at: pH 7.4-7.6, Alkalinity 80-120 ppm, and Salt 2700-5000 ppm.
Strict Exclusions: The manufacturer warranty explicitly excludes damage resulting from freezing (improper winterization), improper water flow rates, and chemical imbalance/corrosion.
Swimming Pool Service Area
Greater Toronto Area (GTA) and surrounding regions
Toronto, Markham, Richmond Hill, Vaughan, Aurora, Newmarket, Scarborough, Brampton, and Mississauga.
Extended Service Area: Stouffville, Oshawa, Barrie, Orangeville, Hamilton, St. Catharines, Guelph, Kitchener.
Frequently Asked Questions
Is the Hayward HP115CLEE1 suitable for extending the swimming season in Southern Ontario?
Yes. With a verified low-ambient output of 56,300 BTU/hr, this variable-speed heat pump is specifically engineered to extract ambient heat from cooler air, effectively extending your swimming season in the Canadian climate when paired with a solar blanket.
What electrical modifications are required to install this heat pump?
The unit requires a dedicated 208-230V electrical circuit, an appropriately sized breaker, a local disconnect switch at the pad, and strict adherence to ESA equipotential bonding codes to ensure absolute safety.
How does the variable-speed inverter compressor save money?
Unlike traditional single-speed heaters that run at 100% power and shut off repeatedly, the inverter compressor scales its output precisely to match the heating demand, maintaining the set temperature with up to 50% less electrical consumption.
Can I purchase this unit and install it myself to save on costs?
No. Installation by an uncertified individual will void the manufacturer’s warranty. Furthermore, improper electrical bonding or incorrect hydraulic flow calibration poses severe safety risks and guarantees premature equipment failure.
Why is maintaining specific water chemistry critical for this heat pump?
The titanium heat exchanger requires a precise chemical balance (pH 7.4-7.6, Alkalinity 80-120 ppm). Deviating from these parameters causes rapid corrosion or scale buildup, which permanently destroys the unit and voids all manufacturer warranties.
Do I need a bypass valve installed with this heat pump?
Yes. To ensure the water flow remains within the strict 16 to 40 GPM requirement, our technicians install a bypass manifold. This protects the heat exchanger from high-pressure damage caused by oversized filtration pumps.