Carrier Air Conditioner
60,000 BTU Carrier Furnace + 2 Ton Heat Pump (Up to 1,800 sq ft Homes)
Carrier 2 Ton Comfort 26SCA4 Air Conditioner – 24,000 BTU Up to 16 SEER2 Central AC
Carrier Comfort™ 2 Ton AC | R410-A Puron
Lennox Air Conditioner
Lennox ML14XC1-024 2 Ton 14 SEER Central Air Conditioner
Lennox ML14XC1-030 2.5 Ton 14 SEER Central Air Conditioner
Lennox ML14XC1-036 3 Ton 14 SEER Central Air Conditioner
Moov Air Conditioner
Midea 2 Ton Central AC Unit – 24,000 BTU Cooling Power, 208/230V System
Midea 2.5 Ton Air Conditioning System – 30,000 BTU Performance, 208/230V
Midea 3 Ton Central Air Conditioner – 36,000 BTU Cooling Capacity, 208/230V
Napoleon Air Conditioner
Napoleon 2 Ton Premium 14.3 SEER2 Central Air Conditioner WTBCS0024RA1
Napoleon 2.5 Ton Premium 14.3 SEER2 Central Air Conditioner WTBCS0030RA1
Napoleon 3 Ton Premium 14.3 SEER2 Central Air Conditioner WTBCS0036RA1
Air Conditioner Services in Greater Toronto Areas and Southern Ontario
Carrier Comfort™ 26SCA4 Air Conditioner – Supplied & Professionally Installed by 4Most Energy
The Carrier Comfort™ 26SCA4 air conditioner is a reliable cooling solution designed to deliver dependable performance and moderate energy savings for residential homes. With up to 16 SEER2 cooling efficiency, this Comfort Series unit offers an ideal balance between cost, performance, and long-term reliability. It features a single-stage compressor that operates at full capacity during cooling cycles, ensuring steady indoor comfort throughout the summer season.
Carrier designed the 26SCA4 with durability in mind. Its WeatherArmor™ cabinet protection includes a galvanized steel cabinet with a protective baked-on powder finish and wire coil guard to help resist corrosion, dents, and environmental wear. This durable design helps ensure the outdoor condenser performs reliably in varying weather conditions.
Proper installation is essential for achieving the performance and efficiency Carrier equipment is designed to deliver. During a professional air conditioner installation in Toronto or the GTA, licensed HVAC technicians must ensure proper refrigerant line sizing, electrical connections, airflow balancing, and correct outdoor unit placement. The system is part of a split-system configuration, meaning the outdoor condenser works together with an indoor evaporator coil connected by refrigerant lines.
Correct system sizing is particularly important in Ontario homes. Oversized or undersized air conditioners can reduce comfort, increase operating costs, and shorten equipment lifespan. A professional load calculation ensures the correct tonnage and airflow configuration for the home.
At 4Most Energy, our licensed gas and refrigeration technicians handle the complete installation process including equipment placement, refrigerant line connection, electrical integration, and system commissioning to ensure your Carrier cooling system operates safely and efficiently.
Carrier AC Comparison Consumer Brochure
Comfort Series Air Conditioners w Puron Advance Consumer Brochure
Warranty:
Carrier provides a 10-year limited parts warranty and 10-year compressor warranty when the product is registered within 90 days of installation. Without registration, warranty coverage is typically 5 years.
Warranty coverage applies to manufacturing defects in materials or workmanship under normal residential use and proper installation by a qualified HVAC technician.
4Most Energy also provides a labour warranty on installation, ensuring professional support should service be required.
Why Install the 26SCA4 with 4Most Energy?
- Up to 16.0 SEER2 cooling efficiency for moderate energy savings.
- Single-stage compressor operating at full capacity for consistent cooling.
- WeatherArmor™ cabinet protection with galvanized steel construction and powder-coat finish.
- Compatible with Carrier smart thermostats and ecobee for Carrier systems.
- InteliSense™ diagnostic technology compatibility for system monitoring.
- Designed for dependable performance with Puron Advance® (R-454B) refrigerant systems.
- Quiet operation with sound levels as low as 72 dBA.
| Specification | Details |
|---|---|
| Specification | Carrier 26SCA4 |
| Model | Carrier 26SCA4 |
| Product Type | Split-System Central Air Conditioner |
| Cooling Efficiency | Up to 16 SEER2 |
| Compressor Type | Single-Stage |
| Sound Level | As low as 72 dBA |
| Refrigerant | Puron Advance® (R-454B) |
| Cabinet Protection | WeatherArmor™ galvanized steel cabinet |
| System Type | Split system with indoor evaporator coil |
| Thermostat Compatibility | Carrier Smart Thermostat, ecobee for Carrier |
| Diagnostic Compatibility | InteliSense™ connected system |
Air Conditioner Sizing Guide
| Model Size | Cooling Capacity | Recommended Home Size | Occupants |
|---|---|---|---|
| 1.5 Ton | 18,000 BTU | Up to ~900 sq ft | 1–2 |
| 2 Ton | 24,000 BTU | 900–1,200 sq ft | 2–3 |
| 2.5 Ton | 30,000 BTU | 1,200–1,500 sq ft | 2–3 |
| 3 Ton | 36,000 BTU | 1,500–1,900 sq ft | 3–4 |
| 3.5 Ton | 42,000 BTU | 1,900–2,200 sq ft | 4–5 |
| 4 Ton | 48,000 BTU | 2,200–2,600 sq ft | 4–5 |
| 5 Ton | 60,000 BTU | Up to ~3,000 sq ft | 5+ |
- Request Installation Quote
Homeowners request a quote online or by phone for a new air conditioner installation. - System Sizing Consultation
Our HVAC specialists evaluate home size, insulation levels, and ductwork to determine the correct AC capacity. - Equipment Recommendation
We recommend the appropriate Carrier system and cooling capacity. - Installation Scheduling
Installation appointments are scheduled at a convenient time. - Removal of Existing System
Existing outdoor condenser and related components are safely removed and disposed. - Installation & System Connection
The new outdoor unit, refrigerant lines, and electrical components are installed and connected to the indoor coil. - Combustion & Electrical Safety Testing
Electrical connections, refrigerant pressures, and airflow are verified. - System Commissioning
Final startup testing ensures proper cooling performance and thermostat communication.
Installation Includes
- Carrier air conditioner unit
- Standard installation materials
- Refrigerant line connection
- Electrical disconnect installation
- System startup and testing
Installation Excludes
- Major ductwork modifications
- Electrical panel upgrades
- Structural modifications
Homeowner's Manual for Split System Air Conditioners Using R-454B Refrigerant
Payment Process
A deposit may be required to schedule installation with the remaining balance due upon completion.
Warranty Claim Process
Contact 4Most Energy service support
Technician diagnosis and verification
Carrier warranty claim submission
Replacement parts installed if approved
Optional Maintenance Plan
Maintenance plans starting from $12.99/month help protect your HVAC investment.
Annual maintenance typically includes:
Condenser coil inspection and cleaning
Refrigerant pressure testing
Electrical connection inspection
Fan motor and capacitor testing
Thermostat calibration
System performance testing
Regular maintenance improves energy efficiency, reduces breakdown risk, and extends system lifespan.
Service Area
Greater Toronto Area (GTA) and surrounding regions
Toronto, Markham, Richmond Hill, Vaughan, Aurora, Newmarket, Scarborough, Brampton, and Mississauga.
Extended Service Area: Stouffville, Oshawa, Barrie, Orangeville, Hamilton, St. Catharines, Guelph, Kitchener.

